02 6260 1888 | 10 Raws Cres, Hume ACT 2620 Australia

AccuFlow

AccuFlow cartridge is a precision filter product that combines the benefit of both a prefilter and final filter in one device to provide reliable and consistentperformance. The pleated filter medium is Accupor membrane, i.e., modified polyethersulfone hydrophilic membrane specifically developed by AF for many filtration applications. 

 

This cartridge is designed for long service and can be used for final filtration when absolute particle removal is necessary, or prefiltration where highly fine particle removal is desired to protect the final filter.

 

During the manufacturing process, each AccuFlow cartridge is flushed with proper solvents under controlled conditions to provide cleanliness, and integrity tested to assure product quality.

 

AccuFlow cartridge is compatible with autoclave and in-line steam sterilization, as well as chemical sanitization methods.

 

Performance Advantages

 

  • Constructed of only two materials, i.e., modified polyethersulfone and polypropylene with no adhesives to ensure lower extractables
  • All components meet USP Class VI-121°C Plastics Tests for biosafety, and are listed as being acceptable for food contact applications according to the Code of Federal Regulation, Title 21
  • Provides high throughputs to minimize filter change-outs during batch processing
  • Enhanced porosity of Accupor membrane as a filter medium in the cartridge results in low differential pressures and extended filter life
  • Offers great resistance to severe sanitizing agents such as hot water, concentrated hydrogen peroxides, and active chloride compounds
  • Available in a variety of configurations allowing easy installation in common-used filtration system
  • 100% integrity tested during manufacturing to assure product reliability and quality

 

Typical Applications

 

Pharmaceuticals and Biologicals: Parenterals, Ophthalmics, Oral and topical medicines, Serum, Tissue culture media, Wash and rinse water, Diagnostic reagents, Buffers, Vaccines, Bottle and vial washers, Dry compressed gases, Make-up water

 

Food and Beverages: Alcohols, Mineral water, DI and RO water, Dry compressed gases, Juices and other potable liquids

 

Bulk Chemicals: Selected acids, Diluted bases, Alcohols

 

Inks: Water and alcohol based inks

 

Electronics: Photoresists, Acids, Etchants, Bases, Solvents, Electroless nickel plating solutions, Pretreatment of DI and RO water

Materials of Construction

Filter Media: Serial layers of pleated Accupor membrane, i.e., modified polyethersulfone hydrophilic membrane

 

  • Support Material: Polypropylene
  • Structure Components: Polypropylene
  • Sealing Technology: Thermal Bonding

Nominal Length

  • 10, 20, 30 and 40 inch
  • (25.4, 50.8, 76.2 and 101.6 cm)

Diameter

  • 2.7 inches (6.9 cm) 

Nominal Pore

  • Size 0.1, 0.2 and 0.45 um

Typical Effective Filtration Area

  • 5.8 ft2 (0.54 m2) per 10 inch

Maximum Operating Temperature*

  • 90 °C (194 °F) at 30 psi (2.1 bar)

*Supported adapters are recommended for applications at elevated temperature over 60 °C

Sterilization/Sanitization Methods

Chemical: Peracetic acid, chlorinated alkaline products, bleach, sulfur dioxide, and hydrogen peroxide at typical sanitization concentrations and temperatures

 

  • Hot Water: 88 °C (190 °F) at 5 psi (0.34 bar)
  • Autoclave: 121 °C (250 °F) for 30 minutes up to 10 cycles
  • In-line Steam: 121 °C (250 °F) for 30 minutes at 2 psi (0.14 bar) up to 10 cycles 142 °C (288 °F) for 60 minutes at 2 psi (0.14 bar) up to 5 cycles 

Maximum Differential Forward Pressure

  • 60 psi (4.1 bar) at ambient temperature

 

Maximum Differential Back Pressure

  • 0.1 um: 30 psi (2.1 bar) at ambient temperature
  • 0.2 um: 15 psi (1.0 bar) at ambient temperature
  • 0.45 um: 15 psi (1.0 bar) at ambient temperature

Maximum Continuous Pressure

Limited by housing

 

Recommended Integrity Tests

  • Minimum Bubble Point:
  • 0.1 um: 28 psi (2.0 bar) in ethanol
  • 0.2 um: 45 psi (3.1 bar) in water
  • 0.45 um: 28 psi (2.0 bar) in water

Diffusional Flow in Water: Provided separately*

∗ For more information, please contact us.

Typical Water Flow Rate

  • 0.1 um: 0.4 gpm/psi/10 inch length (2.2 lpm/0.1 bar/25.4 cm length)
  • 0.2 um: 2.2 gpm/psi/10 inch length (12.1 lpm/0.1 bar/25.4 cm length)
  • 0.45 um: 4 gpm/psi/10 inch length (22 lpm/0.1 bar/25.4 cm length)

 

Oxidizable Substances

Filtrate meets USP XXII requirements for purified water with

Biosafety and CFR Title 21

All components meet USP Class VI-121° C Plastics Tests, and are listed as being acceptable for food contact according to the Code of Federal Regulation, Title 21

 

Endotoxin Level

< 0.25 EU/mL utilizing Limulus Amoebocyte Lysate (LAL) test

 

Typical Non-Volatile Residue 

50 ppm per 10 inch

 

Bacterial Retention

Provided separately* 

*For more information, please contact us.

*